Light Emitting Diode Fluorescent Microscopy And Genexpert Mtbrif Assay For The Diagnosis Of Tuberculosis Against Lj Culture Among Patients Attending Ambo Hospital West-central Ethiopia

Microbial, Cellular And Molecular Biology Project Topics

Get the Complete Project Materials Now! »

One of the most important reasons for the high number of tuberculosis (TB)-related deaths in low-income countries is due to the challenge of diagnosis. The simple and cheaper light-emitting diode fluorescent microscopy (LED-FM) having long life-span, not producing ultraviolet (UV) light, minimal power requirements and better performance is recommended by the World Health Organization (WHO), in 2009 to replace the conventional microscopy in both high- and low-volume laboratories. The WHO has also endorsed (in 2010) one more technique, GeneXpert MTB/RIF assay (Xpert), for better TB diagnosis particularly among human immunodeficiency virus (HIV)-infected cases. However, the relative performance of both of these tools differs from setting to setting in reference to culture as a gold standard. This study was, thus, aimed at evaluating these tools for TB detection in individuals visiting Ambo Hospital, west-central Ethiopia. Cross-sectional early-morning sputum samples were collected from presumptive TB patients attending Ambo Hospital between January and August 2015. Socio-demographic data were captured using a semi-structured questionnaire. Clinical information was gathered from patients’ medical records. The sputum samples were diagnosed using LED-FM, Xpert, concentrated Ziehl-Neelsen (cZN) staining and Lowenstein-Jensen (LJ) medium culture. Drug sensitivity test (DST) was also conducted. Totally, 362 sputum samples were collected and processed. Of these, 36(9.9%) samples were positive by LED-FM, 42(11.6%) by cZN and 50(13.8%) by Xpert. All 362 samples were cultured but 22 were contaminated and 8 nontuberculous Mycobacteria (NTM) leaving only 332 with a definite culture status. From these 332, 45(13.6%) had culture-confirmed TB with 11(24.4%) being HIV co-infected. Two samples were rifampicin resistant by both DST and Xpert. The sensitivity, specificity, positive and negative predictive values of LED-FM and Xpert were 77.8, 100, 100 and 96; and 93.3, 98, 97.5 and 98.9% respectively. Xpert demonstrated 100 and 71.4% sensitivity in smear positive-culture positive and smear negative-culture positive sputum samples in detecting MTB respectively and increased MTB detection rate by 28% compared to dLED-FM.

Get Full Work

Report copyright infringement or plagiarism

Be the First to Share On Social



1GB data
1GB data

RELATED TOPICS

1GB data
1GB data
Light Emitting Diode Fluorescent Microscopy And Genexpert Mtbrif Assay For The Diagnosis Of Tuberculosis Against Lj Culture Among Patients Attending Ambo Hospital West-central Ethiopia

193